本目錄是上海(hai)蘇特(te)電氣有(you)限(xian)公司為(wei)您(nin)精心選購的:
30KV/1.1μF(智能/全自動)超低頻高壓發生器
規格:30KV/1.1μF(智能/全自動),適用10kV及以下電壓(ya)電纜、電力電容器、大中型發電機和(he)電動機試驗(yan)。
產品簡介
0.1Hz超低頻技(ji)術(shu)是技(ji)術(shu),是當前電(dian)(dian)(dian)(dian)工委員會推薦的(de)技(ji)術(shu)。新(xin)一代ZSVLF系(xi)列0.1Hz超低頻高壓(ya)(ya)發(fa)生器(qi)是中試高測(ce)自主開發(fa)的(de)核心產(chan)品,它克服了*代機(ji)械式產(chan)品的(de)諸多缺點(dian),性價比(bi)遠(yuan)遠(yuan)高于(yu)同類(lei)進口產(chan)品,特別適用于(yu)絕緣等值(zhi)電(dian)(dian)(dian)(dian)容較大的(de)電(dian)(dian)(dian)(dian)氣設備(例(li)如:電(dian)(dian)(dian)(dian)力(li)電(dian)(dian)(dian)(dian)纜、電(dian)(dian)(dian)(dian)力(li)電(dian)(dian)(dian)(dian)容器(qi)、大中型發(fa)電(dian)(dian)(dian)(dian)機(ji)和電(dian)(dian)(dian)(dian)動機(ji)等)耐壓(ya)(ya)試驗(yan)。
執行標準
DL/T 849.4-2004/2004年國家新(xin)頒布電力行業標(biao)準《超低(di)頻高壓發生器通用技術(shu)條件(jian)》
產品別名
超(chao)(chao)(chao)(chao)低(di)(di)頻(pin)高(gao)壓發生(sheng)(sheng)(sheng)器(qi)、0.1Hz超(chao)(chao)(chao)(chao)低(di)(di)頻(pin)高(gao)壓發生(sheng)(sheng)(sheng)器(qi)、程控超(chao)(chao)(chao)(chao)低(di)(di)頻(pin)高(gao)壓發生(sheng)(sheng)(sheng)器(qi)、超(chao)(chao)(chao)(chao)低(di)(di)頻(pin)交流高(gao)壓試驗裝(zhuang)置(zhi)、超(chao)(chao)(chao)(chao)低(di)(di)頻(pin)耐壓試驗裝(zhuang)置(zhi)、程控超(chao)(chao)(chao)(chao)低(di)(di)頻(pin)高(gao)壓發生(sheng)(sheng)(sheng)器(qi)、智能超(chao)(chao)(chao)(chao)低(di)(di)頻(pin)高(gao)壓發生(sheng)(sheng)(sheng)器(qi)、0.1hz 超(chao)(chao)(chao)(chao)低(di)(di)頻(pin)高(gao)壓發生(sheng)(sheng)(sheng)器(qi)、0.1hz程控超(chao)(chao)(chao)(chao)低(di)(di)頻(pin)高(gao)壓發生(sheng)(sheng)(sheng)器(qi)、超(chao)(chao)(chao)(chao)低(di)(di)頻(pin)發生(sheng)(sheng)(sheng)器(qi)、超(chao)(chao)(chao)(chao)低(di)(di)頻(pin)耐壓裝(zhuang)置(zhi)、超(chao)(chao)(chao)(chao)低(di)(di)頻(pin)高(gao)壓裝(zhuang)置(zhi)
30KV/1.1μF(智能/全自動)超低頻高壓發生器產品特點
1.技(ji)術(shu)先進:采用(yong)數(shu)字變頻技(ji)術(shu),微電(dian)腦控制,升(sheng)壓、降壓、測(ce)量(liang)、保護等測(ce)試過程全自動化
2.操作方便:接線(xian)簡單(dan),傻瓜式操作
3.保(bao)護全(quan)面:多重(zhong)保(bao)護(過壓(ya)保(bao)護、高低(di)壓(ya)側過流保(bao)護),動作迅速(su)(動作時(shi)間≤20ms),儀器安全(quan)可(ke)靠(kao)
4.安全(quan)可靠:控(kong)制(zhi)(zhi)器和高壓發(fa)生器低壓連(lian)接,光電控(kong)制(zhi)(zhi),使用(yong)安全(quan)可靠
5.采用(yong)了高低壓閉環負反饋(kui)控制電路,輸出無容升效應(ying)
6.配置齊全:液(ye)晶(jing)漢字顯(xian)示,自(zi)動存儲,自(zi)動打印
7.測試(shi)范圍(wei)大(da):0.1Hz、0.05Hz及0.02Hz多(duo)頻率選擇,測試(shi)范圍(wei)大(da)
8.體積(ji)小、重量輕:十分利于戶外作業
30KV/1.1μF(智能/全自動)超低頻高壓發生器產品參數
型 號 | 峰值電壓 | 測量范圍 | 重 量 | 用 途 |
ZSVLF-30/1.1 | 30kV | 0.1Hz時≤1.1μF | 控制器:4kg | 10kV及以(yi)下電(dian)壓電(dian)纜、發(fa)電(dian)機(ji)等 |
0.05Hz時≤2.2μF | ||||
0.02Hz時≤5.5μF |
1、使用(yong)電源:220V±10%,50±5%Hz
注意:若使用便攜(xie)式發電(dian)(dian)機供(gong)電(dian)(dian),要求發電(dian)(dian)機輸(shu)出(chu)電(dian)(dian)壓、頻率穩(wen)定(一般要求功率大于3kW,頻率50Hz,電(dian)(dian)壓220V±5%),否則(ze)要使用一些(xie)輔(fu)助措施穩(wen)定發電(dian)(dian)機輸(shu)出(chu)
2、輸出電壓精度:
輸出電(dian)壓峰(feng)值不穩定度:≤1%
輸出電(dian)壓(ya)頻率不(bu)穩定度:≤3%
輸(shu)出電壓(ya)波形畸變率:<5%
3、使用環境:溫(wen)度(du):-100℃~+400℃;濕度(du):≤85%RH
不同發電(dian)(dian)機的單相對地電(dian)(dian)容量
火電 | 水電 | ||||||
發電機容量(MW) | 200 | 300 | 600 | 800 | 125-150 | 300 | 400 |
單相對地(di)電容(μF) | 0.2-0.25 | 0.18-0.26 | 0.31-0.34 | 0.69 | 1.8-1.9 | 1.7-2.5 | 2.0-2.5 |
交聯(lian)聚乙烯絕緣(yuan)單芯電(dian)力電(dian)纜的電(dian)容量(μF/km)
截(jie)面積(ji) mm2電容(rong)μF/km電壓 kV | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 | 240 | 270 |
10 | 0.15 | 0.17 | 0.18 | 0.19 | 0.21 | 0.24 | 0.26 | 0.28 | 0.32 | 0.38 | - |
35 | - | - | - | 0.11 | 0.12 | 0.13 | 0.14 | 0.15 | 0.16 | 0.17 | 0.19 |
選配表
型 號 | 額定電壓 | 帶載能力 | 電源保險管 | 產品結構、重量 |
ZSVLF-30/1.1 | 30kV (峰值) | 0.1Hz,≤1.1µF | 5A | 控制器:4㎏ 升壓器:25㎏ |
0.05Hz,≤2.2µF | ||||
0.02Hz,≤5.5µF | ||||
ZSVLF-40/1.1 | 40kV (峰值) | 0.1Hz,≤1.1µF | 6A | 控制器:4㎏ 升壓器:35㎏ |
0.05Hz,≤2.2µF | ||||
0.02Hz,≤5.5µF | ||||
ZSVLF-50/1.1 | 50kV (峰值) | 0.1Hz,≤1.1µF | 7A | 控制器:4㎏ 升壓器:50㎏ |
0.05Hz,≤2.2µF | ||||
0.02Hz,≤5.5µF | ||||
ZSVLF-60/1.1 | 60kV (峰值) | 0.1Hz,≤1.1µF | 10A | 控制器:4㎏ 一級升壓器(30kV):25㎏ 二級升壓器(qi)(30kV):45㎏ |
0.05Hz,≤2.2µF | ||||
0.02Hz,≤5.5µF | ||||
ZSVLF-70/0.5 | 70kV (峰值) | 0.1Hz,≤0.5µF | 10A | 控制器:4㎏ 一級(ji)升壓器(30kV):25㎏ 二級升壓器(qi)(40kV):50㎏ |
0.05Hz,≤1µF | ||||
0.02Hz,≤2.5µF | ||||
ZSVLF-80/0.5 | 80kV (峰值) | 0.1Hz,≤0.5µF | 12A | 控制器:4㎏ 一級(ji)升壓器(30kV):25㎏ 二級升壓器(50kV):50㎏ |
0.05Hz,≤1µF | ||||
0.02Hz,≤2.5µF |
電纜的超低頻耐壓試驗方法
電纜額定電壓 U0/Un | 交接試驗電壓 | 預防性試驗電壓 | ||
電壓倍數 | 電壓值(kV) | 電壓倍數 | 電壓值(kV) | |
1.8/3 | 3U0 | 5 | 3U0 | 5 |
3.6/6 | 3U0 | 11 | 3U0 | 11 |
6/6 | 3U0 | 18 | 3U0 | 18 |
6/10 | 3U0 | 18 | 3U0 | 18 |
8.7/10 | 3U0 | 26 | 3U0 | 26 |
12/20 | 3U0 | 36 | 3U0 | 36 |
21/35 | 3U0 | 63 | 3U0 | 63 |
26/35 | 3U0 | 78 | 3U0 | 78 |
各種耐壓試驗的比較
比較內容 | 工頻耐壓 | 變頻耐壓 | 0.1Hz耐壓 | 直流耐壓 |
等效性 | 好 | 好 | 好 | 差 |
絕緣破壞性 | 小 | 小 | 小 | 大 |
操作安全型 | 較低 | 較低 | 高 | 較低 |
試驗接線 | 復雜 | zui復雜 | zui簡單 | 復雜 |
設備體積重量 | zui大 | 較大 | 小 | zui小 |